This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

PrefixNamespace IRI
n18https://web.archive.org/web/20080908024937/http:/www.uni-ulm.de/~hhoster/personal/surface_alloys.
category-eshttp://es.dbpedia.org/resource/Categoría:
dcthttp://purl.org/dc/terms/
n35http://dx.doi.org/10.1103/PhysRevLett.65.
wikipedia-eshttp://es.wikipedia.org/wiki/
dbohttp://dbpedia.org/ontology/
n13http://www.nanotimes-corp.
n28http://dx.doi.org/10.1063/1.
foafhttp://xmlns.com/foaf/0.1/
n33http://www.iap.tuwien.ac.at/www/surface/STM_Gallery/
n11http://www.uni-ulm.de/~hhoster/personal/metal_organic.
dbpedia-eshttp://es.dbpedia.org/resource/
prop-eshttp://es.dbpedia.org/property/
n12http://www.uni-ulm.de/~hhoster/personal/self_assembly.
rdfshttp://www.w3.org/2000/01/rdf-schema#
n14http://www.almaden.ibm.com/vis/stm/gallery.
n5http://nanohub.org/resources/
n15http://stacks.iop.org/Nano/15/
n10http://www.mobot.org/jwcross/spm/
n21http://nobelprize.org/educational_games/physics/microscopes/scanning/index.
n26http://rdf.freebase.com/ns/m.
n17http://es.wikipedia.org/wiki/Microscopio_de_efecto_túnel?oldid=129011428&ns=
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
owlhttp://www.w3.org/2002/07/owl#
n24https://web.archive.org/web/20091028073926/http:/www.geocities.com/spm_stm/Project.
n23http://books.google.com/%3Fid=EXae0pjS2vwC&printsec=frontcover%7Ct%C3%ADtulo=
provhttp://www.w3.org/ns/prov#
xsdhhttp://www.w3.org/2001/XMLSchema#
n22http://www.nano.geo.uni-muenchen.de/SW/images/zoom.
n29http://dx.doi.org/10.1088/1468-6996/9/1/
n31http://dx.doi.org/10.1103/PhysRevLett.49.
n32http://dx.doi.org/10.1103/PhysRevLett.50.
dbrhttp://dbpedia.org/resource/
n30http://dx.doi.org/10.1103/PhysRevB.31.
n25http://molecularmodelingbasics.blogspot.com/2009/09/tunneling-and-stm.
n34http://dx.doi.org/10.1103/PhysRevLett.6.
Subject Item
dbpedia-es:Microscopia_de_efecto_tunel
dbo:wikiPageRedirects
dbpedia-es:Microscopio_de_efecto_túnel
Subject Item
dbpedia-es:Microscopia_de_efecto_túnel
dbo:wikiPageRedirects
dbpedia-es:Microscopio_de_efecto_túnel
Subject Item
dbpedia-es:Microscopio_de_efecto_tunel
dbo:wikiPageRedirects
dbpedia-es:Microscopio_de_efecto_túnel
Subject Item
dbpedia-es:Microscopio_de_efecto_túnel
rdfs:label
Microscopio de efecto túnel
rdfs:comment
Un microscopio de efecto túnel (en inglés, Scanning tunneling microscope o STM) es un instrumento para tomar imágenes de superficies a nivel atómico. Su desarrollo en 1981 hizo ganar a sus inventores, Gerd Binnig y Heinrich Rohrer (de IBM Zürich), el Premio Nobel de Física en 1986.​​ Para un STM, se considera que una buena resolución es 0.1 nm de resolución lateral y 0.01 nm de resolución de profundidad.​ Con esta resolución, los átomos individuales dentro de los materiales son rutinariamente visualizados y manipulados. El STM puede ser usado no solo en ultra alto vacío, sino que también en aire, agua, y varios otros líquidos o gases del ambiente, y a temperaturas que abarcan un rango desde casi cero Kelvin hasta unos pocos cientos de grados Celsius.​
owl:sameAs
n26:06xlt
dct:subject
category-es:Inventos_de_Suiza category-es:Introducciones_de_1981 category-es:Ciencia_de_los_años_1980 category-es:Microscopios
foaf:isPrimaryTopicOf
wikipedia-es:Microscopio_de_efecto_túnel
prop-es:autor
Roland Wiesendanger
prop-es:año
1994
prop-es:editorial
dbpedia-es:Cambridge_University_Press
prop-es:isbn
521428475
prop-es:url
http://books.google.com/?id=EXae0pjS2vwC&printsec=frontcover|título=Scanning probe microscopy and spectroscopy: methods and applications
dbo:wikiPageID
4878483
dbo:wikiPageRevisionID
129011428
dbo:wikiPageExternalLink
n5:2620 n10: n11:htm n12:htm n13:com n14:html n15:1135 n18:html n21:html n22:html n23:Scanning n24:html n25:html n28:92999 n29:013003 n30:805 n31:57 n32:120 n33: n34:57 n35:448
dbo:wikiPageLength
29258
prov:wasDerivedFrom
n17:0
dbo:abstract
Un microscopio de efecto túnel (en inglés, Scanning tunneling microscope o STM) es un instrumento para tomar imágenes de superficies a nivel atómico. Su desarrollo en 1981 hizo ganar a sus inventores, Gerd Binnig y Heinrich Rohrer (de IBM Zürich), el Premio Nobel de Física en 1986.​​ Para un STM, se considera que una buena resolución es 0.1 nm de resolución lateral y 0.01 nm de resolución de profundidad.​ Con esta resolución, los átomos individuales dentro de los materiales son rutinariamente visualizados y manipulados. El STM puede ser usado no solo en ultra alto vacío, sino que también en aire, agua, y varios otros líquidos o gases del ambiente, y a temperaturas que abarcan un rango desde casi cero Kelvin hasta unos pocos cientos de grados Celsius.​ El STM está basado en el concepto de efecto túnel. Cuando una punta conductora es colocada muy cerca de la superficie a ser examinada, una corriente de polarización (diferencia de voltaje) aplicada entre las dos puede permitir a los electrones pasar al otro lado mediante el efecto túnel a través del vacío entre ellas. La resultante corriente de tunelización es una función de la posición de la punta, el voltaje aplicado y la (LDOS por sus siglas en inglés) de la muestra.​ La información es adquirida monitorizando la corriente conforme la posición de la punta escanea a través de la superficie, y es usualmente desplegada en forma de imagen. La microscopía de efecto túnel puede ser una técnica desafiante, ya que requiere superficies extremadamente limpias y estables, puntas afiladas, excelente control de vibraciones, y electrónica sofisticada.
Subject Item
dbpedia-es:Microscopía_de_efecto_tunel
dbo:wikiPageRedirects
dbpedia-es:Microscopio_de_efecto_túnel
Subject Item
dbpedia-es:Microscopía_de_efecto_túnel
dbo:wikiPageRedirects
dbpedia-es:Microscopio_de_efecto_túnel
Subject Item
dbpedia-es:Gerd_Binnig
prop-es:conocidoPor
dbpedia-es:Microscopio_de_efecto_túnel
Subject Item
wikipedia-es:Microscopio_de_efecto_túnel
foaf:primaryTopic
dbpedia-es:Microscopio_de_efecto_túnel
Subject Item
dbr:Scanning_tunneling_microscope
owl:sameAs
dbpedia-es:Microscopio_de_efecto_túnel